Чтение онлайн

ЖАНРЫ

Судовые механики. Базовая лексика.
Шрифт:

5. Clean sewage treatment plant once a month with the………………………

Read the text and do exercises:

Bacteria are added at the top point of the system, so they can clean all pipes and the system.

Clean sewage treatment plant once a month with the clean water inlet.

Put missing words in the gaps:

once a month clean all pipes top point of the system

Bacteria are added at the……………………., so they can …………………and the system.

Clean sewage treatment plant ………………… with the clean water inlet.

Put words in correct order to make sentences:

of the system Bacteria top point are added at the, pipes can all so they and the clean system.

…………………………………………………………………………………………………………………………………………………………………………………………………………………………

sewage clean treatment a month Clean with the water plant once inlet.

…………………………………………………………………………………………………………

Answer the questions:

How many tanks are in the sewage treatment plant?

What is barbotage?

Why do bacteria need air?

Why do we add bacteria at the top point of the system?

When do we need to add running water?

How do you perform a sludge test?

Oil mist detector

Oil Mist Detector Part 1

is sucked from

всасывается из

into – в

crankcase – картер

measuring head – измерительная голова

oil mist opacity – непрозрачность масляного тумана

is determined – определяется

compressed air – сжатый воздух

which is connected to – который подсоединен к

pressure regulator – регуляторы давления

set pressure – установить давление

water column – водяной столб

Put words in gaps:

is sucked from всасывается из

into – в

crankcase – картер

measuring head – измерительная голова

oil mist opacity – непрозрачность масляного тумана

Both aircrafts crashed …………….. the ocean.

………………. is the key to activate alarm.

In the………………., oil mist is created when the lubricating oil is splashed by moving and rotating parts of the engine.

An indicator layer on a small glass component installed in the ……………….. is illuminated with blue-green-light.

Water ……………… the barrel with the pump.

is determined – определяется

compressed air – сжатый воздух

which is connected to – который подсоединен к

pressure regulator – регуляторы давления

set pressure – установить давление

water column – водяной столб

The dosage ………………. according to the instructions.

Suction is from the pipeline, ……………………. the camera.

The material flow rate is easily controlled with a ………………………….

It is necessary to …………………. of air, the flow of the coloring composition and the width of the "torch" correctly.

Better use of air for aeration due to the height of the…………………….

Pressure regulating valves – ……………………… control.

Read the text and do exercises:

Oil mist (oil gasses) is sucked from the crankcase into the measuring head.

In measuring head oil mist opacity is determined. We use compressed air, which is connected to the control air. With the help of a pressure regulator we set pressure 60 ml of water column.

Put words in the gaps:

set pressure measuring head oil mist opacity water column is connected to is sucked from

Oil mist (oil gasses) ……………….. the crankcase into the…………………….

In measuring head ……………… is determined. We use compressed air, which ………………… the control air. With the help of a pressure regulator we …………………… 60 ml of……………………..

Put words in correct order to make sentences:

is sucked from the measuring head the crankcase into (oil gasses) Oil mist.

……………………………………………………………………………………………………………

is determined opacity head oil mist In measuring.

……………………………………………………………………………………………………………

is compressed connected to the control air air, which We use

……………………………………………………………………………………………………………

With we set 60 ml of water a pressure pressure the help of column regulator .

……………………………………………………………………………………………………………

Oil Mist Detector Part 2

Firstly –

сперва

siphones – сифоны

ejector sucks mist – эжектор всасывает туман

shock absorbers – амортизаторы

not to pass vibration – не передать вибрацию от

control the condition – контролировать состояние

Put words in gaps:

1. ………………………. from the engine.

2. The automated laboratory was established to ……………………….of the underground section.

3. There were also supplied stabilizers of transverse stability together with hydraulic………………………

4………………… are on the crankcase.

5. We need shock absorbers ……………………………from the engine.

6. But,..............., we need order.

Read the text and do exercises:

Firstly, oil mist goes to the connection box.The mist is from the crankcase. There are pipes on the left and on the right, which are connected with the siphones on the crankcase.

Ejector sucks mist from the engine.

We use shock absorbers not to pass vibration from the engine to the measuring head.

Engineers must control the condition of shock absorbers.

<
Поделиться с друзьями: